Föregående Nästa
Såld den
2022-08-26
# bud
45
OBJEKTSINFORMATION
Mätarställning
74 Timmar
Serie #
25 ft 4 in Max Lift Height, 500 lb Max Weight Capacity, Platform Extension, Power to Platform, Solid Non-Marking Tires, Upper Control Box
***This unit is being listed on SalvageSale and has mechanical deficiencies and/or damage. The operating and/or physical condition of the unit could not be fully verified by IronPlanet and any underlying damage or issues are unknown***

This item is sold AS IS WHERE IS with all faults and no warranties expressed or implied by IronPlanet.

MECHANICAL ISSUES NOTED - PLEASE SEE INSPECTION REPORT

 

Inspektionsrapport


 
Functionality
Beskrivning Uppgifter
Electric The unit only operates from the ground controls. The upper control box is not operational.
Drivetrain The drivetrain engages in forward and reverse. When another control box was used the unit moved.
Hydraulics The hydraulic system is operational.
Deficiencies Deficient Components/Systems Include but are not limited to: Unit was in an accident and caused damaged to scissor structure and control box


Allmänt skick
Beskrivning Bedömning Uppgifter  
Hour Meter / Odometer 74 hrs, Not operationally checked - No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed. Klicka här för att öppna bilder och videofilmer av det här objektet.  
(10)


Control Station Photos
Pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Beskrivning Bedömning Uppgifter  
(5)


Electrical System Photos
Beskrivning Bedömning Uppgifter  
(5)


Drivetrain Photos
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Beskrivning Bedömning Uppgifter  
(4)


Hydraulics Photos
Beskrivning Bedömning Uppgifter  
(2)


Chassis Photos
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Beskrivning Bedömning Uppgifter  
(13)